Event Manager Email Notification Event Error: "P_EventMan_SendFinishedMail..."

Event Manager Email Notification Event Error: "P_EventMan_SendFinishedMail..."

Event Manager - Error
The event failed and reported this error:
P_EventMan_SendFinishedMail : SQL Server blocked access to procedure 'sys.sp_OACreate' of component 'Ole Automation Procedures' because this component is turned off as part of the security configuration for this server. A system administrator can enable the use of 'Ole Automation Procedures' by using sp_configure. For more information about enabling 'Ole Automation Procedures', see "Surface Area Configuration" in SQL Server Books Online.

The error message continues by repeating similar text that begins with 'SQL Server blocked access to procedure...'.


Root Cause:

This can be caused by Microsoft settings on your SQL server.


Workaround:

Have your system administrator use the Microsoft SQL recommendation in the error message, and see the SQL Server Books Online to enable OLE Automation Procedures.

ArticleNumber:

000040985